As the cost of solar electricity has fallen, the number of grid-connected solar PV systems has grown into the millions and utility-scale solar power stations with hundreds of megawatts are being built. Solar PV is rapidly becoming an inexpensive, low-carbon technology to harness renewable energy from the Sun. The current largest photovoltaic power station in the world is the 850 MW Longyangxia Dam Solar Park, in Qinghai, China.
Many of the largest operational onshore wind farms are located in the USA and China. The Gansu Wind Farm in China has over 5,000 MW installed with a goal of 20,000 MW by 2020. China has several other "wind power bases" of similar size. The Alta Wind Energy Center in California is the largest onshore wind farm outside of China, with a capacity of 1020 MW of power.[141] Europe leads in the use of wind power with almost 66 GW, about 66 percent of the total globally, with Denmark in the lead according to the countries installed per-capita capacity.[142] As of February 2012, the Walney Wind Farm in United Kingdom is the largest offshore wind farm in the world at 367 MW, followed by Thanet Wind Farm (300 MW), also in the UK.

FEATURES: Integrated automatic braking system to protect from sudden and high wind speed. Easy DIY installation methods with all materials provided. Can be used in conjunction with solar panels. MPPT Maximum power point tracking built into the wind turbine generator. Made with high quality Polypropylene and Glass Fiber material with a weather resistant seal.


“Volkswagen Converting Zwickau Automotive Plant to Produce Electric Vehicles” • In a move that it believes is the first of its kind in the world for a major car factory, VW is converting its auto factory in Zwickau, Germany from internal combustion vehicle production to manufacture of electric vehicles. The plant makes 330,000 cars per year. [CleanTechnica]
How accurate are these numbers? This is the energy production a good horizontal-axis wind turbine can reach, if installed at the perfect site and height. These are the upper limit though, if your turbine produces anywhere near the number predicted by this table you should be doing your happy-dance! Most small wind turbine installations underperform significantly, in fact, the average seems to be about half of the predicted energy production (and many do not even reach that). There can be many reasons for the performance shortfall; poor site selection,  with more turbulent air than expected often has much to do with it. The reports in the ‘real world’ section following below illustrate this point. Many small wind turbines do not reach 30% overall efficiency, some are close to 0% (this is no joke!), so these numbers have only one direction to go. For off-grid battery charging wind turbines you should deduct 20 – 30% of the predicted numbers, due to the lower efficiency of a turbine tied to batteries, and the losses involved in charging batteries.

Second-generation technologies include solar heating and cooling, wind power, modern forms of bioenergy and solar photovoltaics. These are now entering markets as a result of research, development and demonstration (RD&D) investments since the 1980s. The initial investment was prompted by energy security concerns linked to the oil crises (1973 and 1979) of the 1970s but the continuing appeal of these renewables is due, at least in part, to environmental benefits. Many of the technologies reflect significant advancements in materials.
Solar energy is the cleanest and most abundant renewable energy source available, and the U.S. has some of the richest solar resources in the world. Solar technologies can harness this energy for a variety of uses, including generating electricity, providing light or a comfortable interior environment, and heating water for domestic, commercial, or industrial use.
Micro-hydro configured into mini-grids also provide power. Over 44 million households use biogas made in household-scale digesters for lighting and/or cooking, and more than 166 million households rely on a new generation of more-efficient biomass cookstoves.[26] Clean liquid fuel sourced from renewable feedstocks are used for cooking and lighting in energy-poor areas of the developing world. Alcohol fuels (ethanol and methanol) can be produced sustainably from non-food sugary, starchy, and cellulostic feedstocks. Project Gaia, Inc. and CleanStar Mozambique are implementing clean cooking programs with liquid ethanol stoves in Ethiopia, Kenya, Nigeria and Mozambique.[139]

Most in the industry agree that 11 m/s (24.6 mph) makes for a good rated wind speed. Go above it and very soon the turbine should be hard at work to protect itself from destruction, by furling, governing, or shutting down. Those that do not will likely face a short and tortured life. If we agree on 11 m/s, an equation for a realistic rated power number is as follows:
Similarly, in the United States, the independent National Research Council has noted that "sufficient domestic renewable resources exist to allow renewable electricity to play a significant role in future electricity generation and thus help confront issues related to climate change, energy security, and the escalation of energy costs … Renewable energy is an attractive option because renewable resources available in the United States, taken collectively, can supply significantly greater amounts of electricity than the total current or projected domestic demand."[154]
Concentrating solar power plants with wet-cooling systems, on the other hand, have the highest water-consumption intensities of any conventional type of electric power plant; only fossil-fuel plants with carbon-capture and storage may have higher water intensities.[135] A 2013 study comparing various sources of electricity found that the median water consumption during operations of concentrating solar power plants with wet cooling was 810 ga/MWhr for power tower plants and 890 gal/MWhr for trough plants. This was higher than the operational water consumption (with cooling towers) for nuclear (720 gal/MWhr), coal (530 gal/MWhr), or natural gas (210).[134] A 2011 study by the National Renewable Energy Laboratory came to similar conclusions: for power plants with cooling towers, water consumption during operations was 865 gal/MWhr for CSP trough, 786 gal/MWhr for CSP tower, 687 gal/MWhr for coal, 672 gal/MWhr for nuclear, and 198 gal/MWhr for natural gas.[136] The Solar Energy Industries Association noted that the Nevada Solar One trough CSP plant consumes 850 gal/MWhr.[137] The issue of water consumption is heightened because CSP plants are often located in arid environments where water is scarce.
A regular alternator out of a car needs to be modified to produce anything meaningful above a few volts if any at low RPM. If this guy is not totally bullshit lieing, he is using a modified PMA alternator (permanent magnet alternator) and if not the voltage he is so proudly showing is actually a voltage drop caused by the alternator using power to power it's field coil. This is very misleading to newcomers to the field of renewable energy and makes a mockery of it. And if he really wanted to help people build this he would have should people how to wire the alternator up . Including explaining things like the wires on the regulator the ignition switch , the stator and the field wires. This is why rednecks laugh at liberals because they see shit like this. .
This is a wind map of the lands south of the border (the US) for 30 meters (100′) height, a very common height for small wind turbine installations. Anything green or yellow is not a good wind resource location. Here in Canada the distribution is similar, in that the good places are in the mid-west and very close to the shores of the great lakes and oceans.
With feed-in tariffs, the financial burden falls upon the consumer. They reward the number of kilowatt-hours produced over a long period of time, but because the rate is set by the authorities, it may result in perceived overpayment. The price paid per kilowatt-hour under a feed-in tariff exceeds the price of grid electricity. Net metering refers to the case where the price paid by the utility is the same as the price charged.
Third-generation technologies are not yet widely demonstrated or commercialised. They are on the horizon and may have potential comparable to other renewable energy technologies, but still depend on attracting sufficient attention and RD&D funding. These newest technologies include advanced biomass gasification, biorefinery technologies, solar thermal power stations, hot dry rock geothermal energy and ocean energy.
A hybrid system combines (C)PV and CSP with one another or with other forms of generation such as diesel, wind and biogas. The combined form of generation may enable the system to modulate power output as a function of demand or at least reduce the fluctuating nature of solar power and the consumption of non renewable fuel. Hybrid systems are most often found on islands.
×